Resource StructureDefinition/FHIR Server from package healthdata.be.r4.cbb#0.16.0-beta (78 ms)
Package | healthdata.be.r4.cbb |
Type | StructureDefinition |
Id | Id |
FHIR Version | R4 |
Source | https://simplifier.net/resolve?scope=healthdata.be.r4.cbb@0.16.0-beta&canonical=https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source |
Url | https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source |
Status | draft |
Name | HdBeLaboratoryTestResultSpecimenSource |
Title | HdBe-LaboratoryTestResult.Specimen.Source |
Experimental | False |
Description | Source of obtained specimen material or a microbial isolate that is used in a laboratory analysis. |
Copyright | Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise. |
Type | Device |
Kind | resource |
Resources that use this resource
Resources that this resource uses
Source
{
"resourceType" : "StructureDefinition",
"id" : "HdBe-LaboratoryTestResult.Specimen.Source",
"url" : "https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source",
"name" : "HdBeLaboratoryTestResultSpecimenSource",
"title" : "HdBe-LaboratoryTestResult.Specimen.Source",
"status" : "draft",
"publisher" : "Healthdata.be (Sciensano)",
"contact" : [
{
"name" : "Service portal â healthdata.be",
"telecom" : [
{
"system" : "url",
"value" : "https://sciensano.service-now.com/sp",
"use" : "work"
}
]
}
],
"description" : "Source of obtained specimen material or a microbial isolate that is used in a laboratory analysis.",
"copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
"fhirVersion" : "4.0.1",
"mapping" : [
{
"identity" : "HdBe-LaboratoryTestResult",
"uri" : "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-LaboratoryTestResult",
"name" : "HdBe logical model LaboratoryTestResult"
},
{
"identity" : "zib-laboratorytestresult-v4.6-2020EN",
"uri" : "https://zibs.nl/wiki/LaboratoryTestResult-v4.6(2020EN)",
"name" : "zib LaboratoryTestResult-v4.6(2020EN)"
}
],
"kind" : "resource",
"abstract" : false,
"type" : "Device",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Device",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Device",
"path" : "Device",
"comment" : "The Device that represents the CBB LaboratoryTestResult concept for SpecimenSource."
},
{
"id" : "Device.deviceName",
"path" : "Device.deviceName",
"max" : "1"
},
{
"id" : "Device.deviceName.name",
"path" : "Device.deviceName.name",
"definition" : "If the material is not collected directly from the patient but comes from a patient-related object, e.g. a cathetertip, a specific name of this source of material can be recorded here.",
"alias" : [
"BronMonster"
],
"mapping" : [
{
"identity" : "HdBe-LaboratoryTestResult",
"map" : "LaboratoryTestResult.Specimen.SpecimenSource",
"comment" : "Only if a more specific SpecimenSource name can be provided than specified as type."
},
{
"identity" : "zib-laboratorytestresult-v4.6-2020EN",
"map" : "NL-CM:13.1.29",
"comment" : "SpecimenSource"
}
]
},
{
"id" : "Device.deviceName.type",
"path" : "Device.deviceName.type",
"definition" : "The type of name the device is referred by.",
"comment" : "If type is unknown, use value `other`."
},
{
"id" : "Device.type",
"path" : "Device.type",
"short" : "SpecimenSource",
"definition" : "If the material is not collected directly from the patient but comes from a patient-related object, e.g. a cathetertip, this source of material can be recorded here.",
"comment" : "If a deviceName is known, which is more specific than the type, this name can be added to deviceName.name.",
"alias" : [
"BronMonster"
],
"min" : 1,
"binding" : {
"strength" : "extensible",
"valueSet" : "https://fhir.healthdata.be/ValueSet/SpecimenSource"
},
"mapping" : [
{
"identity" : "HdBe-LaboratoryTestResult",
"map" : "LaboratoryTestResult.Specimen.SpecimenSource"
}
]
},
{
"id" : "Device.patient",
"path" : "Device.patient",
"type" : [
{
"code" : "Reference",
"targetProfile" : [
"http://hl7.org/fhir/StructureDefinition/Patient",
"https://fhir.healthdata.be/StructureDefinition/HdBe-Patient"
]
}
]
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.