FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package healthdata.be.r4.cbb#0.16.0-beta (78 ms)

Package healthdata.be.r4.cbb
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=healthdata.be.r4.cbb@0.16.0-beta&canonical=https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source
Url https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source
Status draft
Name HdBeLaboratoryTestResultSpecimenSource
Title HdBe-LaboratoryTestResult.Specimen.Source
Experimental False
Description Source of obtained specimen material or a microbial isolate that is used in a laboratory analysis.
Copyright Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.
Type Device
Kind resource

Resources that use this resource

StructureDefinition
https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen HdBe-LaboratoryTestResult.Specimen

Resources that this resource uses

StructureDefinition
https://fhir.healthdata.be/StructureDefinition/HdBe-Patient HdBe-Patient
https://fhir.healthdata.be/ValueSet/SpecimenSource SpecimenSource


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "HdBe-LaboratoryTestResult.Specimen.Source",
  "url" : "https://fhir.healthdata.be/StructureDefinition/HdBe-LaboratoryTestResult.Specimen.Source",
  "name" : "HdBeLaboratoryTestResultSpecimenSource",
  "title" : "HdBe-LaboratoryTestResult.Specimen.Source",
  "status" : "draft",
  "publisher" : "Healthdata.be (Sciensano)",
  "contact" : [
    {
      "name" : "Service portal – healthdata.be",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://sciensano.service-now.com/sp",
          "use" : "work"
        }
      ]
    }
  ],
  "description" : "Source of obtained specimen material or a microbial isolate that is used in a laboratory analysis.",
  "copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion" : "4.0.1",
  "mapping" : [
    {
      "identity" : "HdBe-LaboratoryTestResult",
      "uri" : "https://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-LaboratoryTestResult",
      "name" : "HdBe logical model LaboratoryTestResult"
    },
    {
      "identity" : "zib-laboratorytestresult-v4.6-2020EN",
      "uri" : "https://zibs.nl/wiki/LaboratoryTestResult-v4.6(2020EN)",
      "name" : "zib LaboratoryTestResult-v4.6(2020EN)"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Device",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Device",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Device",
        "path" : "Device",
        "comment" : "The Device that represents the CBB LaboratoryTestResult concept for SpecimenSource."
      },
      {
        "id" : "Device.deviceName",
        "path" : "Device.deviceName",
        "max" : "1"
      },
      {
        "id" : "Device.deviceName.name",
        "path" : "Device.deviceName.name",
        "definition" : "If the material is not collected directly from the patient but comes from a patient-related object, e.g. a cathetertip, a specific name of this source of material can be recorded here.",
        "alias" : [
          "BronMonster"
        ],
        "mapping" : [
          {
            "identity" : "HdBe-LaboratoryTestResult",
            "map" : "LaboratoryTestResult.Specimen.SpecimenSource",
            "comment" : "Only if a more specific SpecimenSource name can be provided than specified as type."
          },
          {
            "identity" : "zib-laboratorytestresult-v4.6-2020EN",
            "map" : "NL-CM:13.1.29",
            "comment" : "SpecimenSource"
          }
        ]
      },
      {
        "id" : "Device.deviceName.type",
        "path" : "Device.deviceName.type",
        "definition" : "The type of name the device is referred by.",
        "comment" : "If type is unknown, use value `other`."
      },
      {
        "id" : "Device.type",
        "path" : "Device.type",
        "short" : "SpecimenSource",
        "definition" : "If the material is not collected directly from the patient but comes from a patient-related object, e.g. a cathetertip, this source of material can be recorded here.",
        "comment" : "If a deviceName is known, which is more specific than the type, this name can be added to deviceName.name.",
        "alias" : [
          "BronMonster"
        ],
        "min" : 1,
        "binding" : {
          "strength" : "extensible",
          "valueSet" : "https://fhir.healthdata.be/ValueSet/SpecimenSource"
        },
        "mapping" : [
          {
            "identity" : "HdBe-LaboratoryTestResult",
            "map" : "LaboratoryTestResult.Specimen.SpecimenSource"
          }
        ]
      },
      {
        "id" : "Device.patient",
        "path" : "Device.patient",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "https://fhir.healthdata.be/StructureDefinition/HdBe-Patient"
            ]
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.